cdm7160 arduino

CDM7160-C00 - Pre-calibrated CO2 Module PRODUCT …

():CDM7160-C00-,Brand of Product:Figaro,Part#:CDM7160-C00,CDM7160,Data Type:Datasheet,Language:,Date. Sign in / Register. Home New Products Technical Resources Supplier Cooperation. Integrated Circuits Discrete Components Connectors & Structural Components Assembly Unit & Modules & Accessories Power Supplies & Power Modules Electronic Materials Test …

Get Price

Chat With WhatsApp

CDM7160-C00 LTA – Unitronic GmbH

CDM7160-C00 LTA Menge. In den Warenkorb. Artikelnummer: 23716 Kategorien: GASSENSOREN, SENSOREN FÜR LUFTQUALITÄT, SENSORMODULE Schlagwort: FIGARO. Beschreibung Beschreibung. Carbon Dioxide (CO2) Sensor Modul for measurement air quality Non-Dispercive Infrared (NDIR) Technology Power Supply: 4,75 .. 5,25 VDC Current consumption: 60mA peak, 10mA avg. …

Get Price

Chat With WhatsApp

CO2-Sensoren

CO2-Sensor CDM7160. 2019. Der CDM7160 basiert auf dem optischen Prinzip. Er ist zur CO2-Messung in Wohnungen und Büros geeignet. Der CO2-Sensor ist auch als Bausatz oder schon fertig bestückte Platine lieferbar. siehe: BS-CDM7160. nach oben. CO2-Sensor TGS4160. Lieferung bis der Lagerbestand erschöpft ist. nach oben. CO2-Sensor TGS4161. Lieferung bis der Lagerbestand …

Get Price

Chat With WhatsApp

CDM7160 - Pre-calibrated CO2 Module

CDM7160 module is designed for simple integration into a user's products. It can be used in a wide range of applications such as ventilation controls for the improvement of energy savings and to assure a good indoor climate. Dimensions 1 1 17 32 5 6 1 11 5 6 1 11 26 Non-woven fabric Hole diameter VDD GND ALARM PWM CAD0 NC RX/SCL TX/SDA BUSY CAL MSEL …

Get Price

Chat With WhatsApp

CDM7160 footprint, schematic symbol and 3D model by Figaro

CDM7160 — Figaro. - Low Design Risk. Design Risk Rank is determined by in-depth analysis across multiple factors, including part availability, functional equivalents, lifecycle and more. → Risk Rank. Risk Rank is a proprietary algorithm Supplyframe has developed to quantify component risk using multiple data points. This ranking helps engineers and buyers determine whether ...

Get Price

Chat With WhatsApp

Add Support for CDM7160 / Figaro sensor · Issue #986 ...

· Used pull-up resistors 1K for both SCL (CDM7160 PIN 10) and SDA (CDM7160 PIN9) CDM7160 PIN1 - VDD +5V, CDM7160 PIN2 GND; Dont forget to enable I2C as default mode is UART, CDM7160 MSEL (PIN6) connect to GND. Module default I2C address is 0X69 For testing used this; Copy link Ingrown29 commented Mar 9, 2019. Hi guys, I have the same sensor and I want to make it work …

Get Price

Chat With WhatsApp

CDM7160-C00 - Pre-calibrated CO2 Module

CDM7160 module is designed for simple integration into a user's products. It can be used in a wide range of applications such as ventilation controls for the improvement of energy savings and to assure a good indoor climate. Dimensions 1 1 17 32 5 6 1 11 5 6 1 11 26 Non-woven fabric Hole diameter VDD GND ALARM PWM CAD0 NC RX/SCL TX/SDA BUSY CAL MSEL …

Get Price

Chat With WhatsApp

TECNICA INFORMATION FOR CDM7160 - Turnkey Instruments

CDM7160 has two calibration functions. One isbackground calibration, the other is zero calibration. Withbackground calibration, CO2 concentration output is set at 400ppm, assuming the sensor is exposed to 400ppm CO2(normal CO2 levels in clean air are approx. 400ppm). With zero calibration, CO2 concentration output is set at 0ppm, assuming the sensor is exposed to 0ppm CO2. For further …

Get Price

Chat With WhatsApp

CDM7160 - Pre-calibrated CO2 Module

The CDM7160 CO2 module uses a compact NDIR CO2 sensor, featuring excellent performance characteristics, including high accuracy and low power consumption. Two detector elements inside the module make absolute measurement possible. Every module is individually calibrated and is provided with both a UART and I2C digital interface. The CDM7160 module is designed for simple integration …

Get Price

Chat With WhatsApp

GitHub - SandboxElectronics/NDIR: Arduino Library for ...

· Restart the Arduino IDE. The library should now be ready for use. It is recommended to use the automatic way because it automatically places the libraries to the correct path. For manual installation, the path of folder can be found by clicking File->Preferences in the Arduino IDE. The Sketchbook location is on the top of the Preferences page.

Get Price

Chat With WhatsApp

Technical Information for the CDM7160 CO Module

The factory default setting of CDM7160 for atmo-spheric pressure and altitude is fixed at hPaand 0m. Since CDM7160 has pressure and altitudedependency, compensation for atmospheric pressure and altitude is needed to obtain high accuracy under different pressures/altitudes. To compensate, please refer to the document CDM7160 CommunicationSpecifications.

Get Price

Chat With WhatsApp

TECNICA INFORMATION FOR CDM7160 - Turnkey Instruments

CDM7160 can be mounted on a mother printed circuit board by soldering the φ terminal holes of the sensor to pin strips of a pitch. R1 C1 1µF R2 OUT(0-5V) 0V 100 100k PWM(Pin 4) Fig. 4 - PWM signal conversion circuit 0 1000 2000 3000 4000 5000 6000 0 100 200 300 400 500 Display Reading (ppm) Time (days) 0ppm 400ppm 1000ppm 2000ppm 3000ppm 5000ppm N=4 Fig. 5 - Long …

Get Price

Chat With WhatsApp

Senzor CO2 – SensorWiki

Software - Arduino IDE; CDM7160-C00 Kalibrovaný modul senzoru plynu CO 2, NDIR 300-5000 ppm. Obr. 1:Modul senzoru cdm7160-c00. Senzor funguje na základe NDIR (Non-Dispersive InfraRed) spektrometrie. Meranie koncentrácie CO 2 je založené na princípe absorpcie infračerveného svetla v jednoznačnej a presne určenej vlnovej dĺžke (v prípade CO 2 je to µm). Túto vlnovú dĺžku ...

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us